Use the laboratory evidence without turning it into a certificate.

Two manufacturer timber-floor samples were tested under the FIBA Equipment & Venue Centre programme in 2020. Both reports record a PASS against the submitted Level 2 wooden-floor requirements, while explicitly stating that the reports are not Certificates of Approval.

L2laboratory test-requirement scope
Supply-only project pathwayCurrent construction documents reviewedFIBA test evidence kept configuration-specific2020 laboratory results separated from current approval status

What the supplied reports establish

Tested samples passed. Current approval remains a separate question.

The evidence is useful because it records the construction type and measured performance of the submitted single-keel and double-keel samples. It does not establish a current FIBA approval certificate for today's ATHREN supply configuration.

Confirmed

Report type

FIBA Equipment & Venue Centre Approval Programme laboratory test reports · wooden flooring.

Confirmed

Test result

Single-keel and double-keel submitted samples both recorded PASS against the Level 2 requirements covered by their reports.

Boundary

Approval status

The reports expressly say they are not Certificates of Approval. Current approval/listing is confirmed separately where required.

Documented laboratory reference

Measured performance from the 2020 test samples.

These figures come from the manufacturer samples submitted to the FIBA Equipment & Venue Centre laboratory-test programme. They are useful performance evidence, but the reports are not Certificates of Approval and do not by themselves prove that the current production build is unchanged.

Performance propertySingle-keel test sampleDouble-keel test sample
Report resultPASS against submitted Level 2 wooden-floor requirementsPASS against submitted Level 2 wooden-floor requirements
Force reduction57%55%
Vertical deformation1.6 mm1.6 mm
Ball rebound93%93%
Slip resistance8684
Resistance to wear53 mg68 mg
Rolling-load indentation0.37 mm0.44 mm

Evidence boundary: these are documented results for submitted 2020 samples. Current production equivalence, current governing-body approval/listing and any project-specific certification requirement are checked separately before quotation.

Claim boundaries

What we are not publishing.

These guardrails stay in place unless supported by the applicable project documentation.

Not claimed

01

Any claim that ATHREN T-S1 or T-D2 is currently FIBA Approved

Not claimed

02

Any claim of current FIBA certification without a current certificate or official listing

Not claimed

03

Any extension of the 2020 test results to portable, floating or materially different floor constructions

Next evidence pack

What still needs current confirmation.

The 2020 test results can now be published as historical laboratory references. The remaining work is to connect them cleanly to today's production and close the current compliance documentation.

01

Current production equivalence to the 2020 tested samples

Held until current manufacturer or project documentation confirms the requirement.

02

Current FIBA Certificate of Approval / official listing

Held until current manufacturer or project documentation confirms the requirement.

03

EN 14904 evidence

Held until current manufacturer or project documentation confirms the requirement.

04

Fire performance

Held until current manufacturer or project documentation confirms the requirement.

05

Formaldehyde / VOC evidence

Held until current manufacturer or project documentation confirms the requirement.

06

Current warranty and maintenance schedule

Held until current manufacturer or project documentation confirms the requirement.

Use exact evidence

Competition claims are confirmed against the quoted floor.

For project documentation, the exact construction, sport requirement and—where required—the current approval certificate or official listing are checked together before an approval statement is issued.

Start Project Brief

Direct project answers

What project teams need to know about this ATHREN timber-flooring pathway.

Evidence-controlled answers for system selection, specification and project review.
01

What is ATHREN Timber Flooring FIBA Test Evidence?

Two 2020 manufacturer timber-floor samples were tested under the FIBA Equipment & Venue Centre Approval Programme and recorded as PASS against submitted…

02

What projects are suitable for athren timber flooring fiba test evidence?

Typical project pathways include residential projects, commercial projects, hospitality projects, and international projects. Final suitability depends on the exact configuration, site conditions, operating requirements and destination.

03

What information is needed to specify athren timber flooring fiba test evidence?

Before specification or quotation, the project review should confirm: Verified product specifications or documented product facts; Clear applications, limitations and configuration boundaries; Project inputs required for manual quotation or technical review; Apollo supply-only scope and purchaser/local-project responsibilities. Claims are kept tied to the exact proposed system rather than transferred from a related product or reference configuration.

04

Can Apollo NZ Global supply athren timber flooring fiba test evidence internationally?

Apollo can supply suitable projects internationally where the product and destination pathway are current. Send the project location, intended use, dimensions or quantities, timing, relevant drawings or photographs, and any known performance, compliance or environmental requirements for review.