Skip to main content
Apollo NZ Global
Get a QuoteMy Project
Configure CADARN

CADARN · Technical Centre

Technical planning for the actual kitset being ordered.

Use this centre to coordinate CADARN sizing, structure, controls, drainage, exposure, enclosure and supply-only responsibilities before the project is finalised.

CADARN boundaryMaximum 6 × 4 m / 24 m². Larger-span, linked, reduced-column or more bespoke architectural louvre projects move to ARKEN.

Apollo Technical System · CADARN

Move between product, configuration, documents and project brief.

Quick reference

Current CADARN planning data.

These figures are useful for first-stage coordination. Final structural, fixing, electrical and accessory requirements remain configuration and site dependent.
SystemModular aluminium louvre pergola kitset
Maximum footprint6 × 4 m / 24 m²
Standard coloursBlack · White · Grey
Frame / louvre coloursMatching or mixed combinations
Custom colourFlaxpod Matt · additional cost
Standard heightApprox. 2.5 m
Extended posts3.0 m · supplied full length for site cutting
OperationManual or motorised
Frame materialPowder-coated 6063-T5 aluminium
Standard post100 × 100 × 2.0 mm
Main beam120 × 45 × 2.0 mm
Louvre blade150 × 30 × 1.5 mm
Standard fixings304 stainless steel
Coastal upgrade316 stainless steel fixing pathway
LightingIntegrated surround LED pathway
Manufacturing warrantyLifetime warranty pathway*
Powder-coat warranty15-year standard / 10-year coastal pathways*
Developer / reseller brandingLaser-marked logo on selected aluminium posts · production confirmation required
Mixed roof pathwayLouvre roof · polycarbonate roof · frame-only zones within CADARN envelope
CADARN structural profile reference showing 100 by 100 by 2 millimetre post, 120 by 45 by 2 millimetre main beam and 150 by 30 by 1.5 millimetre louvre blade
CADARN structural profile referencePost 100 × 100 × 2.0 mm · Main beam 120 × 45 × 2.0 mm · Louvre blade 150 × 30 × 1.5 mm.

Build sequence

Six decisions before manufacture.

Most avoidable project problems come from freezing the product before the support, water, power or enclosure interfaces are known.
01

Footprint

Confirm width, projection and finished-height intent. CADARN stops at 6 × 4 m / 24 m².

02

Support

Identify slab, footing, deck, wall or existing frame conditions before manufacture.

03

Exposure

Record open, coastal, snow/cold or other demanding exposure conditions early.

04

Water

Nominate the site discharge route for water leaving the integrated roof drainage system.

05

Power

For motorised systems and LED lighting, confirm how electrical supply will reach the system.

06

Enclosure

Freeze screen, glass, louvre-wall or decorative-panel intent before final drilling and accessory coordination.

System coordination

What needs to be resolved by discipline.

Structure + foundations

Confirm supporting capacity, post positions, anchors, wall fixing zones, deck framing or existing-frame suitability. CADARN is supply-only. The purchaser independently arranges and manages local structural design, foundations, approvals and onsite works.

Drainage

Closed louvres direct roof water into integrated gutter and internal drainage pathways. The project still needs a practical discharge route, with the outlet-bearing columns and final connection identified before installation.

Electrical + controls

Motorised systems use electric roof operation with remote control, the current smart-control pathway and rain-sensor functionality. Integrated LED lighting also requires electrical connection even where the roof itself is manual.

Enclosure

Current CADARN pathways include retractable screens, decorative privacy panels, fixed aluminium louvre walls, adjustable open/close louvre walls and selected sliding-glass modules. Coordinate these before drilling or final manufacture.

Coastal + warranty

Powder-coated aluminium and stainless hardware support outdoor use. Qualifying standard-environment installations have a 15-year powder-coat warranty pathway; qualifying coastal installations have a 10-year coastal powder-coat warranty pathway. Coastal projects can also be reviewed with a 316 stainless fixing upgrade, while freshwater cleaning and maintenance remain important in salt-exposed environments.

Delivery + assembly

Confirm destination, unloading, safe component movement and assembly access. The kitset pathway does not include on-site assembly, lifting equipment, local electrical connection or final drainage connection unless expressly stated.

Optional outdoor heating

Selected projects can be coordinated with an IP65 weather-rated outdoor-heater pathway. Final heater model, wattage, voltage, controls, mounting position, clearances, electrical design and warranty must be confirmed before quotation or specification.

Mounting pathways

What changes between freestanding, wall-mounted and roof-only CADARN.

The roof system may be similar, but the project information needed before manufacture is different for each support condition.

Freestanding

Confirm the overall footprint, finished roof height, post positions, slab / footing or deck-support condition, anchor zones, finished levels, drainage discharge, electrical route where required and safe assembly access.

Wall-mounted

Confirm the actual structural wall or framing zone, fixing height, wall straightness, cladding / cavity / soffit / fascia conditions where relevant, and the project-specific flashing and sealing detail. CADARN should not be fixed only to decorative cladding.

Roof-only retrofit

Measure the existing timber, steel or aluminium frame accurately at multiple points. Confirm internal opening dimensions, support spacing, member sizes, level, squareness, fixing faces and structural capacity for the completed roof, wind and fixing loads.

Water interfaces

For all pathways, nominate where integrated roof drainage will discharge. Wall-mounted and retrofit projects also need the gutter, flashing, existing-roof and building-envelope interfaces resolved locally.

Electrical interfaces

Motorised roofs require a practical electrical supply route. Integrated LED lighting also requires power even when the roof itself is manual. Cable routes and connection points should be planned before final installation.

Mixed roof zones

Selected CADARN projects can combine louvre, polycarbonate and frame-only zones inside the overall 6 × 4 m / 24 m² CADARN envelope. Larger linked structures or more bespoke structural arrangements move to ARKEN.

Installation references

Raw interface photographs, kept where they are technically useful.

These supplied-system reference photos are not presentation imagery. They are retained here to help explain real connection and wall-interface conditions during project coordination.
Real CADARN blind hardware connection reference
Blind hardware referenceReal bracket and connection detail from the supplied-system pathway. Final fixing position depends on the selected bay and screen configuration.
Real CADARN wall-side track and flashing interface reference
Wall-interface referenceReal wall-side track and flashing reference. Final flashing, sealing and building-envelope detailing remain project-specific.

Enclosure reference

Plan the outdoor room as one system.

Side systems share the beam and post zone with drainage, lighting and fixings, so accessory choices should be known before manufacture wherever possible.
Retractable screensGuided manual / motorised + manual crank pathways

Current screen families use 30% polyester / 70% PVC fabric. Nominal opening compatibility depends on the selected screen family.

Sliding glassSelected 3 m and 4 m bay modules

Current pathway uses 8 mm tempered glass in an aluminium sliding frame. Clear opening, track, floor level and drainage interface require project confirmation.

Louvre wallsFixed + adjustable pathways

Fixed and open/angle/close side-louvre options are available for selected bay sizes, with final profile, panel layout and operating hardware confirmed per project.

Decorative panelsPrivacy + feature screening

Selected laser-cut aluminium panels can be integrated as architectural side screens or partial privacy elements rather than weather-sealed walls.

Accessory compatibility

Match the enclosure to the actual bay.

This matrix shows the currently documented nominal opening pathways. “Standard” means a current module/pathway is documented for that nominal opening. “Review” means Apollo must confirm the opening, post spacing, fixing and combination before manufacture.
CADARN accessory2.0 m3.0 m3.6 m4.0 mOtherCurrent pathway note
Guided retractable screenReviewStandardReviewStandardReviewManual or motorised guided screen pathway is currently documented for nominal 3 m and 4 m bays.
Manual crank retractable screenReviewStandardStandardStandardReviewCurrent manual-crank pathway is documented for nominal 3.0 m, 3.6 m and 4.0 m openings.
Sliding glass wallReviewStandardReviewStandardReviewCurrent supplied modules are approximately 2700 × 2375 mm and 3700 × 2375 mm for nominal 3 m and 4 m bays.
Fixed aluminium louvre wallReviewStandardStandardStandardReviewCurrent fixed-wall pathway is documented for nominal 3.0 m, 3.6 m and 4.0 m bays.
Adjustable open / close louvre wallReviewStandardReviewStandardReviewCurrent adjustable full-wall pathway is documented for nominal 3.0 m and 4.0 m bays.
Decorative privacy / feature panelsReviewReviewReviewReviewReviewPattern, panel count, post spacing, fixing points and adjacent accessories are confirmed project by project.

Important: the overall CADARN pergola footprint is not automatically the same as an enclosure bay width. Final clear opening, posts, tracks, floor levels, drainage and adjacent accessories are confirmed against the actual ordered configuration.

CADARN kitset supply

What can arrive as part of the system.

  • Aluminium posts, beams, gutters and structural brackets
  • Manual or motorised adjustable-louvre roof components
  • Integrated surround LED lighting pathway
  • Selected controls, remote and sensor components where applicable
  • Standard hardware and specified fixing package
  • Selected CADARN enclosure accessories where ordered
  • Assembly, care and project-specific supplied documentation

Local / project works

What normally stays with the site team.

  • Foundations, slabs or structural strengthening
  • On-site assembly and safe working access
  • Electrical supply and final connection
  • Final drainage connection and site discharge
  • Wall flashing, sealing and building-envelope interfaces
  • Unloading, lifting equipment and site handling
  • Local engineering, approvals and consenting where required

Next step

Confirm the configuration, then request your project quote.

Project