CADARN · Technical Centre
Technical planning for the actual kitset being ordered.
Use this centre to coordinate CADARN sizing, structure, controls, drainage, exposure, enclosure and supply-only responsibilities before the project is finalised.
Apollo Technical System · CADARN
Move between product, configuration, documents and project brief.
BUILT INTELLIGENCE
Research connected to this project pathway.
Can an existing timber, steel or aluminium frame support a motorised louvre roof? Review structure, size, drainage, fixings and NZ project requirements before ordering.
Read intelligence Outdoor systemsEnclosing a Pergola: Zip Screens, Sliding Glass or Fixed Privacy Panels?Compare zip-screen outdoor blinds, sliding glass and fixed privacy panels for NZ pergolas, including shade, wind, rain, views, drainage and support requirements.
Read intelligence Outdoor systemsFibreglass vs Concrete Swimming Pools in NZ: What Really Changes?Compare fibreglass and concrete swimming pools in NZ by design flexibility, factory production, access, lifting, finishes, ground conditions, barriers and long-term care.
Read intelligenceSee your CADARN before requesting a quote.
Browse the 15 CADARN configuration visualisations by size and mounting type. Standard 2.5 m post height applies to freestanding and wall-attached drawings; roof-only fits inside an existing supporting structure.

4 corner posts
Illustrative standard configuration; final dimensions and supporting details are reviewed before manufacture. Not a project-specific engineering drawing.Quick reference
Current CADARN planning data.
These figures are useful for first-stage coordination. Final structural, fixing, electrical and accessory requirements remain configuration and site dependent.
Build sequence
Six decisions before manufacture.
Most avoidable project problems come from freezing the product before the support, water, power or enclosure interfaces are known.Footprint
Confirm width, projection and finished-height intent. CADARN stops at 6 × 4 m / 24 m².
Support
Identify slab, footing, deck, wall or existing frame conditions before manufacture.
Exposure
Record open, coastal, snow/cold or other demanding exposure conditions early.
Water
Nominate the site discharge route for water leaving the integrated roof drainage system.
Power
For motorised systems and LED lighting, confirm how electrical supply will reach the system.
Enclosure
Freeze screen, glass, louvre-wall or decorative-panel intent before final drilling and accessory coordination.
System coordination
What needs to be resolved by discipline.
Structure + foundations
Confirm supporting capacity, post positions, anchors, wall fixing zones, deck framing or existing-frame suitability. CADARN is supply-only. The purchaser independently arranges and manages local structural design, foundations, approvals and onsite works.
Drainage
Closed louvres direct roof water into integrated gutter and internal drainage pathways. The project still needs a practical discharge route, with the outlet-bearing columns and final connection identified before installation.
Electrical + controls
Motorised systems use electric roof operation with remote control, the current smart-control pathway and rain-sensor functionality. Integrated LED lighting also requires electrical connection even where the roof itself is manual.
Enclosure
Current CADARN pathways include retractable screens, decorative privacy panels, fixed aluminium louvre walls, adjustable open/close louvre walls and selected sliding-glass modules. Coordinate these before drilling or final manufacture.
Coastal + warranty
Powder-coated aluminium and stainless hardware support outdoor use. Qualifying standard-environment installations have a 15-year powder-coat warranty pathway; qualifying coastal installations have a 10-year coastal powder-coat warranty pathway. Coastal projects can also be reviewed with a 316 stainless fixing upgrade, while freshwater cleaning and maintenance remain important in salt-exposed environments.
Delivery + assembly
Confirm destination, unloading, safe component movement and assembly access. The kitset pathway does not include on-site assembly, lifting equipment, local electrical connection or final drainage connection unless expressly stated.
Optional outdoor heating
Selected projects can be coordinated with an IP65 weather-rated outdoor-heater pathway. Final heater model, wattage, voltage, controls, mounting position, clearances, electrical design and warranty must be confirmed before quotation or specification.
Mounting pathways
What changes between freestanding, wall-mounted and roof-only CADARN.
The roof system may be similar, but the project information needed before manufacture is different for each support condition.Freestanding
Confirm the overall footprint, finished roof height, post positions, slab / footing or deck-support condition, anchor zones, finished levels, drainage discharge, electrical route where required and safe assembly access.
Wall-mounted
Confirm the actual structural wall or framing zone, fixing height, wall straightness, cladding / cavity / soffit / fascia conditions where relevant, and the project-specific flashing and sealing detail. CADARN should not be fixed only to decorative cladding.
Roof-only retrofit
Measure the existing timber, steel or aluminium frame accurately at multiple points. Confirm internal opening dimensions, support spacing, member sizes, level, squareness, fixing faces and structural capacity for the completed roof, wind and fixing loads.
Water interfaces
For all pathways, nominate where integrated roof drainage will discharge. Wall-mounted and retrofit projects also need the gutter, flashing, existing-roof and building-envelope interfaces resolved locally.
Electrical interfaces
Motorised roofs require a practical electrical supply route. Integrated LED lighting also requires power even when the roof itself is manual. Cable routes and connection points should be planned before final installation.
Mixed roof zones
Selected CADARN projects can combine louvre, polycarbonate and frame-only zones inside the overall 6 × 4 m / 24 m² CADARN envelope. Larger linked structures or more bespoke structural arrangements move to ARKEN.
Installation references
Raw interface photographs, kept where they are technically useful.
These supplied-system reference photos are not presentation imagery. They are retained here to help explain real connection and wall-interface conditions during project coordination.

Enclosure reference
Plan the outdoor room as one system.
Side systems share the beam and post zone with drainage, lighting and fixings, so accessory choices should be known before manufacture wherever possible.Current screen families use 30% polyester / 70% PVC fabric. Nominal opening compatibility depends on the selected screen family.
Current pathway uses 8 mm tempered glass in an aluminium sliding frame. Clear opening, track, floor level and drainage interface require project confirmation.
Fixed and open/angle/close side-louvre options are available for selected bay sizes, with final profile, panel layout and operating hardware confirmed per project.
Selected laser-cut aluminium panels can be integrated as architectural side screens or partial privacy elements rather than weather-sealed walls.
Accessory compatibility
Match the enclosure to the actual bay.
This matrix shows the currently documented nominal opening pathways. “Standard” means a current module/pathway is documented for that nominal opening. “Review” means Apollo must confirm the opening, post spacing, fixing and combination before manufacture.| CADARN accessory | 2.0 m | 3.0 m | 3.6 m | 4.0 m | Other | Current pathway note |
|---|---|---|---|---|---|---|
| Guided retractable screen | Review | Standard | Review | Standard | Review | Manual or motorised guided screen pathway is currently documented for nominal 3 m and 4 m bays. |
| Manual crank retractable screen | Review | Standard | Standard | Standard | Review | Current manual-crank pathway is documented for nominal 3.0 m, 3.6 m and 4.0 m openings. |
| Sliding glass wall | Review | Standard | Review | Standard | Review | Current supplied modules are approximately 2700 × 2375 mm and 3700 × 2375 mm for nominal 3 m and 4 m bays. |
| Fixed aluminium louvre wall | Review | Standard | Standard | Standard | Review | Current fixed-wall pathway is documented for nominal 3.0 m, 3.6 m and 4.0 m bays. |
| Adjustable open / close louvre wall | Review | Standard | Review | Standard | Review | Current adjustable full-wall pathway is documented for nominal 3.0 m and 4.0 m bays. |
| Decorative privacy / feature panels | Review | Review | Review | Review | Review | Pattern, panel count, post spacing, fixing points and adjacent accessories are confirmed project by project. |
Important: the overall CADARN pergola footprint is not automatically the same as an enclosure bay width. Final clear opening, posts, tracks, floor levels, drainage and adjacent accessories are confirmed against the actual ordered configuration.
CADARN kitset supply
What can arrive as part of the system.
- Aluminium posts, beams, gutters and structural brackets
- Manual or motorised adjustable-louvre roof components
- Integrated surround LED lighting pathway
- Selected controls, remote and sensor components where applicable
- Standard hardware and specified fixing package
- Selected CADARN enclosure accessories where ordered
- Assembly, care and project-specific supplied documentation
Local / project works
What normally stays with the site team.
- Foundations, slabs or structural strengthening
- On-site assembly and safe working access
- Electrical supply and final connection
- Final drainage connection and site discharge
- Wall flashing, sealing and building-envelope interfaces
- Unloading, lifting equipment and site handling
- Local engineering, approvals and consenting where required
Next step