Skip to main content
Apollo NZ GlobalStart Project Brief
Auremont Container Pools

Auremont Technical Centre

Technical planning for a configured modular pool.

Use this centre to understand the Auremont standard-size modular system, compare cover and installation pathways, and see what must be confirmed before foundations, lifting and services are locked. Configuration-specific dimensions and performance remain tied to the final project documents.

Factory-prepared systemShell, structure and equipment are coordinated together.

The project starts with a standard Auremont size, then selected options and the final equipment package are resolved before manufacture.

Water systemHydraulics are a package, not isolated add-ons.

Pump, filter, heater, treatment and return pathways need to work together and remain serviceable after site completion.

Local project worksFoundation, crane and connections stay site-specific.

Support, retaining, drainage, electrical connection, barriers, landscaping and approvals depend on the destination project.

Technical releaseApproved CAD and equipment schedule control.

Published planning diagrams explain the system, while current project documents control the actual supplied pool.

Auremont · technical drawing set

Understand the system before final project release.

These planning drawings explain the Auremont shell, service zone, water route, installation levels, architectural options and delivery logic. Final project CAD and the confirmed equipment schedule control manufacture and installation.

P-01
AUREMONT TECHNICAL REFERENCE

System anatomy

The modular pool is planned as a coordinated shell, structure, insulation and service system rather than a standalone vessel.

AUREMONTPLANNING REFERENCE / NOT FOR CONSTRUCTION
FRP POOL INTERIORINSULATION ZONESTEEL SUPPORT STRUCTURESERVICE / EQUIPMENT BAYHYDRAULIC CONNECTION ZONEPublished Auremont size identifies the standard model pathway · final internal swim area, freeboard, water depth and equipment-bay geometry are confirmed on approved CAD
P-02
AUREMONT TECHNICAL REFERENCE

Installation routes

The same modular pool concept can meet the landscape at different levels, but structure, drainage and service access change with each route.

AUREMONTPLANNING REFERENCE / NOT FOR CONSTRUCTION
ABOVE GROUNDPARTIAL RECESSDECK INTEGRATEDINGROUNDFoundation, retaining, drainage, service clearance, barriers and finished levels remain destination / site responsibilities unless specifically included
P-03
AUREMONT TECHNICAL REFERENCE

Water + treatment flow

Filtration, heating and treatment are selected as one hydraulic package and confirmed on the final equipment schedule.

AUREMONTPLANNING REFERENCE / NOT FOR CONSTRUCTION
PUMPFILTERHEATINGTREATMENT / CONTROLSKIM / SUCTIONFILTERED / HEATED RETURNExact pump flow, filter size, heater output, pipe sizes, treatment equipment and turnover rate remain configuration / project confirmed
P-04
AUREMONT TECHNICAL REFERENCE

Equipment-bay service logic

The pool remains maintainable only if the service zone stays ventilated, drained and accessible after landscaping and decking are complete.

AUREMONTPLANNING REFERENCE / NOT FOR CONSTRUCTION
PUMPFILTERHEATERCONTROLSSERVICE ACCESS DOORVENTILATION PATHBAY DRAINAGE / DRY ACCESSFinal bay dimensions, component positions, door swing and replacement clearances are confirmed against the supplied equipment package
P-05
AUREMONT TECHNICAL REFERENCE

Acrylic viewing-window interface

The clear viewing panel is an architectural option whose opening, reinforcement and seal geometry are resolved before manufacture.

AUREMONTPLANNING REFERENCE / NOT FOR CONSTRUCTION
ACRYLIC PANELREINFORCED OPENINGSEAL / RETAINING INTERFACEPROJECT-SPECIFIC WINDOW SIZE + THICKNESSDo not infer window thickness, maximum span or structural capacity from a representative image · current project documentation must control
P-06
AUREMONT TECHNICAL REFERENCE

Cover system pathways

Three cover levels can be configured, but motor, structure, travel space and any safety / load performance must be verified for the selected system.

AUREMONTPLANNING REFERENCE / NOT FOR CONSTRUCTION
MANUALAUTOMATICSLIDING DECKMANUAL · simple baseline cover pathwayAUTOMATIC · motor + controls + power require confirmationSLIDING DECK · structure, rails, travel + documented load evidence requiredNo safety, child-resistance or load-bearing claim should be made unless the exact supplied cover has current supporting test evidence for the destination requirement
P-07
AUREMONT TECHNICAL REFERENCE

Delivery + placement workflow

Pool delivery is planned backwards from final placement: receiving route, crane setup and site readiness are resolved before dispatch.

AUREMONTPLANNING REFERENCE / NOT FOR CONSTRUCTION
01FACTORY QAconfigured unit02TRANSPORTroute + envelope03CRANE LIFTweight + lift points04PLACEMENTsupport + servicesBefore dispatch: approved CAD · dry weight · transport envelope · lifting information · receiving route · foundation / support readinessCrane selection and lift planning must use the configured unit's current shipping / lifting documents rather than generic container-pool assumptions

Current standard size range

Keep the four existing Auremont sizes as the commercial starting point.

The published size range stays unchanged. Final project CAD clarifies the actual internal swim area, water depth, freeboard, service bay and configured external envelope.

Auremont cover systems

Three clear cover pathways instead of one generic option.

The cover should be selected early because it can affect power, edge geometry, service access, deck layout and the space needed beside the pool.

01Baseline pathway

Manual / Roller Cover

The simplest current cover route. A manual roller can be coordinated where it suits the pool edge and surrounding layout.

Project confirmationCover material + dimensionsRoller / storage positionCompatibility with selected steps and edge detailsLocal pool-safety requirements
02Powered pathway

Automatic PVC Cover

Motorised flexible-cover operation for projects wanting faster day-to-day opening and closing, subject to the selected pool and destination requirements.

Project confirmationPVC cover specificationMotor + control modelPower supply and isolationCover recess / roll geometryCompatibility, servicing and local safety requirements
03Premium powered pathway

Automatic Slatted Cover

Retractable rigid/slatted cover pathway where a more architectural powered closure is preferred.

Project confirmationSlat material + profileMotor + control modelPower supply and isolationRecess / roll geometryCompatibility, servicing and local safety requirements
04Architectural pathway

Sliding WPC Deck Cover

A moving deck-style cover can transform the closed-pool condition into usable surrounding space, but it requires detailed project information and local structural coordination.

Project confirmationDeck structure + rail layoutClear travel / parking zoneDrainage and controlsVerified load / safety evidence for the exact supplied system

Cover claim control: do not describe a cover as load-bearing, child-resistant, compliant or safety-rated unless the exact supplied cover has current supporting evidence applicable to the destination requirement.

Technical data structure

Each Auremont project is organised around a controlled technical schedule.

Confirmed project values are organised into clear shell, equipment, hydraulic, electrical, delivery and ownership categories so the supplied package can be reviewed as one coordinated system.

01 · Shell + structure

FRP interior · insulated shell system · configured support structure

Exact laminate, insulation and structural details are confirmed from current production documentation.

02 · Equipment package

Pump · filter · heater · lighting · controls

Exact brand, model, flow, power and electrical load are locked on the final equipment schedule.

03 · Equipment layout

Integrated equipment · concealed / buried plant · project-matched remote plant

The selected plant arrangement must preserve access, drainage, ventilation and future component replacement while remaining hydraulically suitable for the configured pool.

04 · Hydraulics

Skimming / suction · filtration · heating · treatment · return

Pipe sizes, materials, valves, turnover rate, backwash and waste connections remain project-confirmed.

05 · Electrical

Heating · lighting · controls · treatment · powered cover where selected

Destination voltage/frequency, connected load and protection requirements are confirmed before production.

06 · Delivery

Configured transport envelope · dry weight · lift points

Crane planning must use final order documentation rather than generic container dimensions.

07 · Site preparation

Support points · levels · drainage · retaining · service clearances

Foundation and surrounding works follow the configured pool, local ground conditions and destination engineering rather than a generic slab detail.

08 · Plumbing interfaces

Fill / top-up · backwash / waste · equipment drainage

Destination plumbing routes and discharge requirements are coordinated before decks, walls and landscaping close access.

09 · Warranty

Structure · shell · equipment · accessories · selected options

Applicable warranty periods, exclusions and claim requirements are confirmed in the final order documentation rather than assumed from generic marketing material.

10 · Maintenance

Water balance · filtration · equipment access · cover care · exposed-material inspection

Final operation and maintenance documents are issued against the supplied package and should remain with the project record.

11 · Contractor handover

CAD · equipment schedule · lifting data · service interfaces · manuals

The destination contractor pack should contain the configured information needed to prepare, receive, place, connect and maintain the pool.

Quality & production testing

Build the evidence pack around the exact pool being supplied.

Auremont separates confirmed project records from configuration-specific claims. Where a test method, material value, certification or warranty is still being confirmed, the website does not invent a number; the final production and release documents control.

01 · QA CONTROL

Pre-production release

Approved CAD · option schedule · equipment schedule

Manufacture should proceed only after the shell-changing options, equipment package and supplied scope are frozen for the project.

02 · QA CONTROL

Shell + structure evidence

FRP build-up · support structure · insulation · coatings

Current material and construction evidence is retained against the selected production specification. Configuration-specific values are not presented as universal Auremont claims.

03 · QA CONTROL

Viewing-window evidence

PMMA / acrylic grade · thickness · support · sealing

Where a viewing window is selected, the project record should identify the actual material, thickness, support arrangement and relevant test / warranty information.

04 · QA CONTROL

Water / leak testing

Method · duration · acceptance record

The exact factory water / leak test procedure and evidence are requested against the supplied configuration before release. No blanket duration or pressure claim is made until verified.

05 · QA CONTROL

Electrical + equipment checks

Component identity · ratings · controls · destination compatibility

Pump, filtration, heating, lighting, treatment and powered options should be traceable to the final equipment schedule and destination electrical requirements.

06 · QA CONTROL

Release documentation

Final weight · transport envelope · lift data · manuals · warranty

The shipment release pack should give the destination team the configured information needed for freight, lifting, placement, connection, ownership and future service.

Evidence rule: structural, laminate, corrosion, acrylic-window, water-test, electrical, certification and warranty claims are published only when they are supported by current documentation for the production specification being offered.

Delivery + site release

Do not pour the final slab or book the crane from a generic pool listing.

The configured Auremont order should provide the actual support information, shipping dimensions, dry weight and lifting details needed by the destination project team. Delivery planning then works backwards from final placement.

01Confirm selected pool + options02Approve project CAD03Issue configured lifting / shipping data04Confirm foundation + crane plan05Receive, place + connect locally

Auremont project brief

Information that moves an idea into a configured pool project faster.

Early-stage projects can proceed with partial information, but access and installation level should be considered before surrounding site works become fixed.

01One of the four current Auremont standard sizes
02Above-ground, partially recessed, deck-integrated or inground intent
03Site dimensions and finished levels
04Truck access, crane setup area and approximate lift route
05Power, water, drainage and backwash / waste pathway
06Acrylic viewing-window interest and preferred side / location
07Manual / roller, automatic PVC, automatic slatted or sliding WPC deck-cover pathway
08Integrated, concealed / buried or remote filtration / plant preference
09WPC exterior / deck integration
10Baja shelf, steps, pool + spa or counter-current intent and desired swim-current level
11White / RGB lighting preference and water-feature interest
12Owner care / cleaning equipment package interest
13Salt, UV, automatic backwash or other water-treatment preference
14Coastal, island, high-humidity or exposed-site conditions
15Site photos, plan / sketch and target timing

Need Apollo to review it?

Turn the result into a project brief.

Project